HP Netserver LPr NetRAID-3Si Cluster Config Guide for Windows NT4.0 Clusters

2
Service pack SP6a or later
SPU
Model HP NetServer LPr
Clock speed 400, 450, 500, 550, 600, 650, 700, 800, 850 MHz.
No. of CPUs 2
BIOS version 4.06.09 PR or later (400, 450 MHz with Rack Storage/12 D5989A)
4.06.14.PR or later (400, 450 MHz with Rack Storage/12 D5989B)
4.06.14.PR or later (500, 550 MHz with Rack Storage/12 D5989B)
4.06.29.PR or later (600, 650, 700 MHz with Rack Storage/12 D5989B)
4.06.32 PR or later (800 MHz with Rack Storage/12 D5989B)
4.06.33 PR or later (850 MHz with Rack Storage/12 D5989C)
CPU cache Any size
RAM 128 MB minimum. Must be HP.
Local storage See Local Storage below.
I/O slots Added cards may be installed in any appropriate slot, keeping in mind the
server's default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, Embedded SCSI, PCI-3, PCI-2, PCI-1, PCI-4
M/S Certified
Configuration
P1 – Local storage (NetRAID-1Si)
P2 - Client LAN
P3 – Shared storage (NetRAID-3Si)
P4 -- Intra-cluster (Heartbeat) LAN
Booted from NetRAID-1Si
Storage
Local
Controller May use embedded SCSI, NetRAID-1Si, or NetRAID-3Si.
Driver For embedded SCSI, use sym_hi.version 4.12 or later. For embedded
DAC and NetRAID-xSi, use mraidnt.sys version 2.24.
Cabinets (physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap
or fixed)
HP only
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI IDs Any
Shared
Controller
Model HP NetRAID-3Si Adapter D5955A
No. of controllers 1
Firmware W.01.30
BIOS B.02.02
Driver Mraidnt.sys 2.24
NetRAID Assistant A.01.15 or later
SCSI ID 6, 7
Channels 0, 1, 2
RAID level 1, 5, 10, 50
Logical disks 1 per RAID array
8 maximum per NetRAID adapter