HP Netserver LPr NetRAID-3Si Cluster Config Guide for Windows NT4.0 Clusters
5
SCSI Channel Cabling for HP Microsoft Cluster Server with Rack Storage/12
NOTES:
2. The NetRAID-3Si Adapter is
installed in server PCI slot P3.
A NetRAID-xSi may also be installed
for connecting local storage drives.
3. Cables between the servers and
shared storage cabinets must be HP
LVD SCSI (offset) of any length up to
10 meters. See “Cables” in Rack
Storage/12 of the guide for a list of
cables by part number that can be used.
1. This diagram depicts using 3
Rack Storage/12s.
LEGEND
Color coding depicts that NetRAID
channels must not be crossed as
they connect from one NetServer
to the other through the shared
storage device. Any channels (0-2)
can be used.
2
0
1
NetRAID-3Si Channels
All channels are for shared
storage use only.