HP Netserver LPr NetRAID-3Si Config Guide for Windows 2000 Advanced Server Clusters

2
System software:
Navigator version L.18.03 or later
Operating System Microsoft Windows 2000 Advanced Server
SPU
Model HP NetServer LPr
Clock speed 850 MHz.
No. of CPUs 2
BIOS version 4.06.33 PR or later
CPU cache Any size
RAM 256 MB minimum. Must be HP.
Local storage See Local Storage below.
I/O slots: Added cards may be installed in any appropriate slot, keeping in mind the
server's default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, Embedded SCSI, PCI-3, PCI-2, PCI-1, PCI-4
M/S Certified
Configuration
P1 – Local storage – NetRAID-1Si
P2 - Client LAN
P3 – Shared storage – NetRAID-3Si
P4 -- Intra-cluster (Heartbeat) LAN
Booted from NetRAID-1Si
Storage
Local
Controller May use embedded SCSI, NetRAID-1Si, or NetRAID-3Si.
Driver For embedded SCSI, use sym_hi.sys from Windows 2000 Adv. Server CD
or later.
For NetRAID-xSi, use mraid35x.sys version 2.62 (Navigator L.18.04.5 or
later).
Cabinets (physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g.,HP Rack
Storage/12), any number.
Disk drives (hot swap
or fixed)
HP only
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI IDs Any
Shared
Controller
Model HP NetRAID-3Si Adapter D5955A
No. of controllers 1
Firmware W.01.30
BIOS B.02.02
Driver Mraid35x.sys 2.62
NetRAID Assistant A.01.15 or later
SCSI ID 6, 7
Channels 0, 1, 2
RAID level 1, 5, 10, 50
Logical disks 1 per RAID array
8 maximum per NetRAID adapter