Compaq 4000/7000 Racks Installation Guide

Chapter 3 Preparing the Rack
30
To mark the slide mounting holes, refer to Figure 3-1 and do the following:
1. On the front columns, count up from the bottom of the installation location
(which is the top of the unit below), marking the 4th and 6th holes.
2. On the rear columns, count up from the bottom of the installation location
(which is the top of the unit below), marking the 4th and 6th holes.
6th
4th
(At Rear
Of Column)
6th
4th
6th
6th
4th
4th
17th
9th
17th
9th
Unit Below
Intended Installation
Location
Figure 3-1. Marking Holes for Installation
3. Now mark two holes on each of the front columns to use for the cage nuts
where the HP NetServer-attachment screws secure to the columns.
4. To mark the HP NetServer-attachment holes on the front columns (refer to
Figure 3-1), count up from the bottom of the installation location (which is
the top of the unit below), marking the 9th, and 17th holes.