HP Netserver LXr 8000 NetRAID-3Si Install. Guide

2
SPU
Model HP NetServer LXr 8000
Clock speed 400, 450, 500, or 550 MHz
No. of CPUs 2 – 4
BIOS version ASPN1.86L.0003 or later (400/450 MHz with Rack Storage/12 Model D5989A)
ASPN Release 10 (400/450 MHz with Rack Storage/12 Model D5989B)
ASPN Release 10 (500/550 MHz)
CPU cache Any size
RAM 256 MB minimum. Must be HP.
No. of power supplies 3
Local storage See Local Storage below.
I/O slots: P3 – P4 Shared storage controller
P1 – NetRAID-3Si local storage
P5 – Client LAN
P6 – Intra-cluster (Heartbeat) LAN
All others – Any other plug-in cards.
Storage
Local
Physical drive location SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/8 or
/12)
Disk drives Must be HP
Controller
May use embedded SCSI or NetRAID-3Si in PCI slot P1 otherwise any
controller listed on the HP Tested Products List.
May not use NetRAID-1, NetRAID-3, or NetRAID-1Si.
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed
Shared
Controller
Model HP NetRAID 3si Adapter D5955A
No. of controllers 1
Firmware W.01.20 or later
BIOS B.01.10 or later
Driver 2.22 or later
NetRAID Assistant A.01.15 or later
SPU I/O slot P3 – P4
SCSI ID 6, 7
Channels 0, 1, 2
RAID level 1, 5, 10, 50
Logical disks 1 per RAID array
Configuration
options:
Cluster mode on
Cache write-policy to write-thru
Set bus speed for Rack Storage/8 to Ultra
Set any other options as you prefer