hp lt 6000r and virtual array config guide - for Microsoft Windows 2000 A.S. Clusters PDF, 226K, 3/8/2002

LT6000R2K2M
8/14/01 5
NetRAID-2M Controllers
0
1
3. Another NetRAID Adapter may be
installed in each server for local
storage (and must connect only to
local storage).
4. This diagram shows use of two
NetRAID-2M controllers, the maximum
supported for shared storage, installed
in slots 5 and 6. One or two NetRAID-2M
cards may be used, and from one to four
RS/12s are supported. A maximum of eight
logical drives are supported for the cluster.
NOTES:
2. Cables between the servers and
shared storage cabinets can be any
HP LVD SCSI cable up to 10 meters.
See Cablesin the Shared Storage
Configuration table in the guide for
a list of cables that can be used.
HP Netserver LT 6000r Cluster using HP Rack Storage/12 Cabling Diagram