Using the BIOS Container Configuration Utility
5 At the Container Properties screen select Delete again and
press Enter.
6 Press Esc to return to the previous menu.
Repairing a RAID 5 Set
Follow these instructions to repair a RAID 5 set:
1 At the BIOS prompt press Ctrl A.
2 Select Container Configuration Utility from the menu.
3 Select Manage Container from the CCU menu.
4 If the BIOS has detected a parity error in the selected RAID 5
set, the following help message is displayed at the bottom of
the screen.
<Ctrl+R> Restore/Enable RAID 5
5 To repair the selected RAID5 set, press Ctrl R and follow the
prompts.
Caution: Be careful when restoring RAID 5 data sets, since
the containers went off-line as a result of some problem.
Data on these sets should not be trusted until the data has
been checked and verified.
!