HP NetRAID-4M Installation Guide
4-11
Installing the Device Drivers
5 When a screen appears that asks you to select a disk driver,
check that the proper driver for any embedded SCSI
controllers is installed.
Note: If the embedded driver has not been installed,
install it before installing the HP NetRAID-4M
drivers. Refer to your Hewlett-Packard server
documentation for further information.
6 Press Insert to install an unlisted driver.
7 Insert the HP NetRAID-4M NOS Driver - NetWare 4
<NetServer Name>driver diskette into your diskette drive.
8 An explanatory screen appears. Press Enter to have the system
scan the diskette for the HP NetRAID-4M driver.
9 Select netr4m.HAM Hewlett-Packard Array Controller and
press Enter.
10 Press Alt-Esc. From the console prompt type the following:
load a:\netraid4m\netr4m.ham
11 Write down the slot number listed for the HP NetRAID-4M
controller (you will need this in a later step) and press Enter.
12 Press Esc twice.
13 At the prompt, press Alt-Esc to return to the installation
screen.
14 Select Select/Modify Driver Parameters, and then press Enter.
15 Type the slot number recorded in step 11.
16 Press F10, or Esc.
17 Select Save Parameters and Continue, and press Enter.
18 To install additional controllers, repeat step 14 through step 17.
19 When finished, select Continue the Installation to complete
the installation.
20 If necessary, modify the load command line in the startup.ncf
file so that the proper path to the driver and all appropriate
command line options are specified. See Loading the NetWare
Drivers at Server Bootup on page 4-17.