HP NetRAID-4M Installation Guide

4-19
Installing the Device Drivers
Openserver
Caution: Before installing the Openserver device drivers for
your HP NetRAID-4M container, ensure that you have
placed the HP NetRAID-4M controller in the correct PCI
slot; otherwise the driver will not install.
For information on supported PCI slots, see the
HP NetRAID-4M Installation Supplement.
a At the initial boot prompt, enter the word link.
b When prompted for the name of additional drivers, enter
the word hpnraid.
c When prompted, insert the diskette you created that
contains the SCO OpenServer 5.0.x Boot NetRAID-4M
driver into your systems diskette drive.
d Complete the Openserver installation.
e When the Openserver installation completes, remove the
driver diskette from the diskette drive and reboot the
system.
f Log onto the system as root and place the SCO
OpenServer 5.0.x Boot NetRAID-4M driver diskette in the
diskette drive.
g Mount the SCO OpenServer 5.0.x Boot NetRAID-4M
driver diskette by entering the following command,
replacing DISKETTE_LUN with the logical unit number that
corresponds to the diskette drive (in most cases, this will be
/dev/fd0):
mount -f S51K /dev/DISKETTE_LUN /mnt
h Run the driver configuration program by entering the
following commands:
cd /mnt/install
!