HP NetRAID-4M Installation Guide

7-5
Installing Clusters
1 If no other shared disks are available, install the MSCS
software and set up the service to use a temporary local
quorum device, as follows. (Later, after the HP NetRAID-4M
Cluster software is installed, you can transfer the quorum to a
shared device, preferably on a diskset resource, as explained in
Moving Quorum to a Shared Container on page 7-6.)
Windows NT systems: Install Microsoft Cluster Service
with Service Pack 6A or higher, by entering the following
command in a command prompt window:
cd \MSCS\cluster\i386
setup -localquorum
Windows 2000 systems: Due to a restriction in Microsoft
Cluster Service, you must start the installation procedure
from the Microsoft Cluster Configuration Wizard, exit the
wizard, and continue installing from the command prompt.
This allows the required files to be copied from the
Microsoft Cluster Service CD and enables you to
temporarily set the local quorum. After exiting the wizard,
enter the following commands in a command prompt
window:
cd %systemroot%\cluster
cluscfg -localquorum
2 When prompted, choose the Form a new cluster option and
specify a name for the cluster.
3 Install the HP NetRAID-4M Cluster software (which is
provided on two diskettes), as follows:
a Start Windows and log on with administrative privileges.
b Insert Diskette #1 of the HP NetRAID-4M Cluster software
kit.
c Click the Start button on the Windows task bar, and then
click Run.
d Type [drive]:\setup and press Enter. Follow the on-
screen instructions.
On each remaining cluster node:
1 Install the MSCS software.