HP Netserver LC 2000 NetRAID-3Si and RS/12 Windows 2000 Advanced Server Cluster Config Guide
Intra-cluster
(Heartbeat) LAN
Embedded NIC with crossover cable. See Intra-cluster LAN below.
Power source Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS. Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version L.18.00 or later
Operating System Microsoft Windows 2000 Advanced Server
SPU
Model HP NetServer LC 2000
Clock speed 933, 1000 MHz
No. of CPUs 2
BIOS version 4.06.23 PV or later (933 MHz)
4.06.29 PV or later (1000 MHz)
CPU cache Any size
RAM 256 MB minimum. Must be HP.
No. of power supplies 1 standard, 2 required for redundancy
Local storage See Local Storage below.
I/O slots Added cards may be installed in any appropriate slot, keeping in mind the
server's default boot order as listed below:
Default Boot Order IDE CD-ROM, FDD, SCSI A, SCSI B, PCI-1, PCI-2, PCI-3, PCI-4,
PCI64-5, PCI64-6
M/S Certified
Configuration
P1 - Local storage - NetRAID-1Si
P3 - Client LAN
P5 - Shared Storage - NetRAID-3Si
Booted from NetRAID-1Si
Storage
Local
Controller May use embedded SCSI, NetRAID-1Si, or NetRAID-3Si.
Driver For embedded SCSI, use sym_hi.sys from Windows 2000 Adv. Server CD
or later.
For NetRAID-xSi, use mraid35x.sys version 2.62 (Navigator L.18.04.5 or
later).
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives Must be HP (hot swap or fixed)
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids Any
Shared
Controller
Model HP NetRAID-3Si Adapter D5955A
No. of controllers 1
Firmware W.01.30
BIOS B.02.02
Driver Mraid35x.sys 2.62