Shared Storage Configuration
Parameter Specification
Containers Single-level or multi-level
Must be fault-tolerant
Eight, maximum, per cluster
Configuration options Write cache disabled
Clustering enabled
Domain validation enabled
Enclosure
Disk drives Any HP drive supported by storage enclosure. Any combination of HP disk
models is allowed in a diskset, on a SCSI channel, or in a cluster.
Number of cabinets Up to eight
Model Rack Storage/12 D5989B, containing two D6025B SCSI controller cards, or
Rack Storage/12 D5989C, containing two D6025C SCSI controller cards
Status SCSI ID 5 (fixed)
Disk SCSI IDs 0–3, 8–15 (fixed)
Cables
SCSI Any two HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
See SCSI cabling diagram on page 5.
Power distribution
Layout Redundant power distribution units (PDUs) are recommended. See power cabling
diagram on page 5.
Microsoft
and HP Certified Server Configuration with NetRAID-1Si
Parameter Specification
I/O card slot PCI slot 1, NetRAID-1Si local storage controller
PCI slot 5, NetRAID-4M shared storage controller
Network interfaces PCI slot 3, Client LAN, model D5013B NIC
Boot device NetRAID-1Si
Microsoft
and HP Certified Server Configuration with NetRAID-1M
Parameter Specification
I/O card slot PCI slot 6, NetRAID-1M local storage controller
PCI slot 5, NetRAID-4M shared storage controller
Network interfaces PCI slot 3, Client LAN, model D5013B NIC
Boot device NetRAID-1M