HP NetServer LC 3 Quick Service Reference Guide Last Updated: April 1999
Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
HP NetServer LC 3 System Information Power Switch Serial Port B Keyboard Lock Serial Port A Fan Parallel Port Mouse Port Keyboard Port Lock Monitor Management Port Flexible Disk Drive EIDE CD-ROM Shelf 3 Hot Swap Drive Bay Fan Power Hot Swap Drive Bay Lock Front Control Panel 1 Power Switch Turns the NetServer on and off. Note that when the NetServer is turned off, the power to the internal circuitry and mass storage devices is disabled; however, AC power is still applied to the power supply.
Removing the Covers CAUTION The covers are an integral part of the server. The server must be operated with the covers in place to ensure proper airflow for continued reliability and to maintain compliance with radio frequency interference and safety standards.
Memory There are four DIMM sockets on the system board for memory expansion Follow these simple rules when you plan to install additional memory DIMMs: • Use only HP DIMMs listed on the Technical Reference Label located inside the HP NetServer top cover, in Information Assistant, or in Order Assistant. • DIMMs can be 32 MB, 64 MB, or 128 MB in any combination. • DIMMs can be installed in any order in any of the four DIMM sockets.
Boot Device Priority The boot device priority is controlled by the Boot Device Ordering submenu of the Configuration menu of the Setup utility. • IDE CD-ROM drive with bootable CD-ROM • Flexible Disk with bootable flexible disk • Embedded SCSI controller • PCI boards in slots in the following order: 6, 5, 4, 3, 2, 1. • Hard Drive Priority: Allows you to rearrange the order in which hard disk drives are searched for the operating system.
² O O O O ² ² ² O ² O O ² O ² ² ² O O ² O ² ² O O O ² ² ² ² O O Voltage Regulator Module for Primary CPU Bad Check that primary voltage regulator module (VRM) is correctly seated. If problem persists, replace VRM. Voltage Regulator Module for Secondary CPU Bad Check that secondary voltage regulator module (VRM) is correctly seated. If problem persists, replace VRM. CPU Over Temperature Check fan for function.
21 20 19 18 22 23 17 16 6
27 26 28 25 29 24 30 7
HP NetServer Replaceable Parts List Fig Replacement Exchange 1 Chassis Assembly 2 Top Cover 5064-1987 3 Side Cover 5064-1986 4 Cage Assy, Hot-Swap Mass Storage 5063-5671 5 Light Pipe 5041-1099 6 Backplane PCA, Hot-Swap Cage 7 Hot Swap Cage Bezel 5042-2108 8 Hot Swap Cage Bezel lock 5064-3503 9 tray, Hot Swap, D3349B D3583-69004 10 5 1/4 inch tray, HDD D2198B 3 pack C2260-60078 Single 11a 4.2 GB SCSI HDD D4910-63001 D4910-69001 11b 9.
29 Front Bezel Assy. 5064-1961 30 Pedestal 5041-5339 * Cable, Non-Hot-Swap SCSI (Wide) 5183-2182 * Cable, IDE CD-ROM Drive 5183-2411 * Cable, Floppy Disk Drive 5183-2410 * Cable, Hot-Swap SCSI (Wide) 5183-2484 Cable, Array SCSI (Wide) 5183-3488 2 * Cable, I C 5182-6730 * Cable, Serial Management 5064-1957 * Network Adapter PCA, 100BaseT * Filler Assy, Hot-Swap 5063-8391 * Upper Drive Filler Panel 5063-8389 * Hot Swap Cage key 5182-4534 * External Battery, 3.
Mass Storage Cables Cabling Label Location A System backplane SCSI connector to upper-shelf SCSI devices 5-connector, wide (68-pin) SCSI cable w/built-in terminator 5183-2412 B System backplane IDE connector to IDE devices (CDROM or other) 3-connector IDE cable 5183-2411 C System backplane floppy connector-to-floppy disk drive 2-connector floppy disk cable 5183-2410 D System backplane (or NetRAID controller) SCSI connector-to- hot-swap backplane 3-connector, wide (68-pin) SCSI cable 5183-24
System Board Illustration Secondary Processor Socket (Terminator Installed In Dual-Ready Configurations) Retaining Latches * Processor Fan Secondary VRM Socket * J20: N/C System Configuration Switches Primary Processor Primary VRM * J17: N/C * J25: 100 MHz Diagnostic LEDs * J26: N/C Memory DIMM Sockets 01 2 3 Battery 0 1 Video Memory Upgrade Sockets 2 3 * Cable connectors labeled with function. Configuration jumpers labeled with default setting. N/C = no jumper header or cable installed.
Specifications Operating Temperature 5°to 35°C (41°to 95°F) Non-operating Temperature -40° to +70° C (-40° to +158° F) Operating Humidity (noncondensing) 20% to 80% relative humidity Non-operating Humidity (noncondensing) 90% relative humidity Operating Altitude 3,045 m (10,000 ft) Non-operating Altitude 12,180 m (40,000 ft) Height 530 mm (21 in) Width 217 mm (8.6 in) Depth 580 mm (23 in) Weight 22 - 25 kg (48 - 55 lb.