hp netserver lc2000 fc config guide - SPOF and SPOFless for Microsoft NT 4.0 Clusters
lc2000ntfc
12/20/01 4
Shared Storage Configuration
Parameter Specification
Hub
Model HP 6-Port Fibre Channel Hub, Model D6976A, or
HP 8-Port Switch, Model P4459A
Quantity One for SPOF
Two for SPOFless with hubs
Microsoft
and HP Certified Server Configuration for Ultra2 Models
Parameter Specification
Server
I/O card slot PCI slot 5, Local storage, NetRAID-1Si
PCI slot 8, Shared storage HBA, HP D8602A
Network interfaces PCI slot 6, Client LAN, HP D5013B
Boot device NetRAID-1Si
Microsoft
and HP Certified Server Configuration for Ultra3 Models
Parameter Specification
Server
I/O card slot PCI slot 5, Shared storage, HBA, HP D8602B
PCI slot 6, Local storage, NetRAID-1M
Network interfaces PCI slot 3, Client LAN, HP D5013B
Boot device NetRAID-1M
Intra-Cluster (Heartbeat) LAN Configuration
Parameter Specification
Network
Connection HP D5954A crossover cable, or equivalent.
The intra-cluster LAN may only be used for cluster node communication. It may
not be used for client communication.
NIC
Quantity One
Model HP 10/100TX PCI, Model D5013A/B
Driver Hptxnt.sys, version 4.02.35 (obtained from Navigator CD-ROM,
version L.20.00), or later