HP Netserver LH 3 NetRAID Installation Guide

HP NetServer Installation Guide 28
NOTE The Client LAN IP addresses and Intra-cluster LAN IP addresses must be on different
subnets.
LXr 8000
These procedures provide instructions for servers using NetRAID, AutoRAID Model 12H, and Model 30/FC
shared storage solutions
Configure NetServer Hardware and BIOS
1. Make sure you power down System A and power up System B.
2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server.
NOTE If prompted that the HP NetServer Navigator BIOS is a newer version, choose
Continue and go to step 3; otherwise go to step 6.
3. To update the BIOS, choose Configuration Assistant, then Custom, Microsoft, MS
Windows NT 4.0 Enterprise Edition, and No for automated NOS installation.
4. Select Update, then Execute. Follow screen prompts to update the BIOS.
5. After the server reboots, return to the Navigator main menu by clicking the Back button twice on the
displayed window.
6. From the Navigator main menu, install a utility partition on the local storage disk by choosing
Configuration Assistant and Installation Assistant, Custom, Microsoft,
then either:
MS Windows NT4.0 Enterprise Edition Cluster Server if using Navigator if
L.15.05 or later.
MS Windows NT 4.0 Enterprise Edition, and No for automated NOS installation if
using Navigator L.15.04 or earlier.
7. Choose Install/Update Utility Partition.
When finished, the system reboots and displays the Custom Configuration window.
8. Make an NT 4.0 Drivers floppy disk by choosing Create Driver Diskette(s), Execute, and
following the prompts. Label the floppy disk NT 4.0 Drivers.