HP Netserver LH 3 NetRAID Installation Guide
2
System software:
Navigator version L.10.00 or later
Operating System Microsoft Windows NT Server 4.0, Enterprise Edition or later
Service pack SP4 or later
SPU
Model HP NetServer LH3
Clock speed 350 or 400 MHz.
No. of CPUs 2
BIOS version 4.06.22 PL or later
CPU cache Any size
RAM 128 MB minimum. Must be HP.
No. of power supplies 2 required, 3 for redundancy
Local storage Internal or external, using any controller except embedded RAID or a
NetRAID-3Si. Must use HP disks. See
Local Storage below.
I/O slots: P7 - P8 Shared storage controller
P1 – Intra-cluster (Heartbeat) LAN
P2 – Client LAN
All others – Any other plug-in cards.
Storage
Local
Controller May not use embedded RAID or a NetRAID-3Si, otherwise any number,
manufacturer or driver in any available I/O slot. However, for NetRAID
local storage use slot P8.
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/8), any number.
Disk drives (hot swap
or fixed)
Must be HP.
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI IDs Any
Shared
Controller
Model HP NetRAID Adapter D4943A
Use with HP Rack Storage/8 (D4902A) and HP Cluster Adapter
(D5957A) only.
No. of controllers 1
Firmware S.01.00
Driver 2.03
NetRAID Assistant A.01.09
SPU I/O slot P7 or P8
SCSI ID 6, 7
Channels 0 and 1 only
Do not use channel 2 for any purpose.
RAID level 1, 5, 10, and 50 only