2
Intra-cluster
(Heartbeat) LAN
HP D5013A/B with crossover cable. See Intra-cluster LAN below.
Power source Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS. Redundant power
distribution units (PDUs) are strongly recommended.
System software:
Navigator version L.18.00 or later
Operating System Microsoft Windows 2000 Advanced Server
SPU
Model HP NetServer LH 4
Clock speed 700 MHz
No. of CPUs 2 - 4
BIOS version 4.06.32 PS or later
CPU cache Any size
RAM 256 MB minimum. Must be HP.
No. of power supplies 3 required, 4 for redundancy
Local storage See Local Storage below.
I/O slots Added cards may be installed in any appropriate slot, keeping in mind the
server's default boot order as listed below:
Default Boot Order IDE CD-ROM, FDD, Embedded A, Embedded B, PCI-8, PCI-7, PCI-6,
PCI-5, PCI-4, PCI-3, PCI-2, PCI-1
M/S Certified
Configuration
P3 - Intra-cluster (Heartbeat) LAN – D5013B
P4 - Client LAN – D5013B
P7 - Shared storage – NetRAID-3Si
P8 - Local storage controller – NetRAID-1Si
Booted from embedded DAC
Storage
Local
Controller May use embedded SCSI, embedded DAC, NetRAID-1Si or NetRAID-
3Si.
Driver For embedded SCSI, use sym_hi.sys from Windows 2000 Adv. Server CD.
For embedded DAC and NetRAID-xSi, use mraid35x.sys version 2.62
(Navigator L.18.04.5 or later).
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives Must be HP (hot swap or fixed)
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids Any
Shared
Controller
Model HP NetRAID-3Si Adapter D5955A
No. of controllers 1
Firmware W.01.30
BIOS B.02.02