HP Netserver LH 4 Surestore E Config Guide for Windows NT4.0 Clusters

2
Navigator version L.15.00 or later
Operating System Microsoft Windows NT Server 4.0, Enterprise Edition
Service pack SP4 or later
SPU
Model HP NetServer LH 4
Clock speed 400 or 450 MHz.
No. of CPUs 2 - 4
BIOS version 4.06.12 PS
CPU cache Any size
RAM 256 MB minimum. Must be HP.
No. of power supplies 3 or 4
Local storage Internal or external. See
Local Storage below.
I/O slots: P6, P7, P8 - Shared storage controller
P2 – Intra-cluster (Heartbeat) LAN
P1 – Client LAN
P3-P5 - Local storage controller or any other plug-in cards.
Storage
Local
Controller Use embedded RAID, otherwise any manufacturer or driver in any
available I/O slot.
Cabinets (Physical drive
location)
SPU internal drive
Disk drives (hot swap
or fixed)
Must be HP.
SCSI IDs Any
Shared
Host Bus Adapter
Model HP A5252B Wide Differential SCSI Adapter.
No. of HBAs 1 – 3 per NetServer.
Driver “Adaptec AHA-294X/AHA-394X/AIC-78XX SCSI Controller”
driver in NT 4.0 SP4 or later
SPU I/O slot P8 (1
st
HBA), P7 (2
nd
HBA), P6 (3
rd
HBA)
SCSI ID 7
Disk Array Controller
Model HP A3706A Model 12H 96MB Controller with SureStore E 12H
No. of controllers 2 per SureStore E 12H
Firmware HP54 or later.
RAID level (internal) 1/0 and 5
Logical disks Logical units within each array must be numbered from 0 – 7.
Hot spare Active Hot Spare.
SCSI ID 0 – 6, or 8 – 15
Disk Array Storage