HP Netserver LH 6000 FC Config Guide for Windows NT4.0 Clusters

2
Operating System
Service Pack
Microsoft Windows
NT Server 4.0, Enterprise Edition
SP6a
SPU
Model HP Netserver LH 6000
Clock speed 700 MHz
No. of CPUs 2 – 6
BIOS version 4.06.26 PU or later
CPU cache Any size
RAM 128 MB minimum. Must be HP.
No. of power supplies 3 standard, 4 required for redundancy
Local storage See Local Storage below.
I/O slots Added cards may be installed in any appropriate slot, keeping in mind
the server's default boot order as listed below:
Default Boot Order IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI64-8,
PCI64-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1
Microsoft
and HP
Certified Configuration
P1 - Client LAN
P8 - Shared Storage – D8602A HBA
Booted from embedded DAC
Storage
Local
Controller May use embedded SCSI, embedded DAC, NetRAID-3Si or NetRAID-
1Si.
For SPOFless, recommend embedded DAC or NetRAID-xSi with drives
in RAID-1 mirror, or another fault tolerant RAID level.
Driver For embedded SCSI, use sym_hi.sys version 4.12 or later.
For embedded DAC or NetRAID-xSi, use mraidnt.sys version 2.24 or
later (Navigator L.18.04.5 or later)
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP.
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids Any
Shared
HP Rack Storage/12FC Required – D5991A
Host Bus Adapter
Model HP Fibre Channel Host Bus Adapter - D8602A
No. of HBAs 1
Driver Hhba5100.sys 2.06
RAID level 0, 1, 3, 5, 10
For SPOFless configurations, a fault-tolerant RAID type, e.g. RAID 5, is
recommended for all shared storage.
Cabinet HP Rack Storage 12/FC – D5991A
RAID arrays Not more than 8 physical drives per logical array and not more than 8
LUNs are permitted per Rack Storage/12FC and Rack Storage/12
combination in a cluster.