Operating System Microsoft Windows NT Server 4.0, Enterprise Edition with Service Pack
SP6A or later
SPU
Model HP NetServer LH6000
Clock speed 550, 700 MHz
No. of CPUs 2 – 6
BIOS version 4.06.21 PU or later (550 MHz)
4.06.26 PU or later (700 MHz)
CPU cache Any size
RAM 256 MB minimum. Must be HP.
Local storage See Local Storage below.
I/O slots Added cards may be installed in any appropriate slot, keeping in mind the
server's default boot order as listed below:
Default Boot Order IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI64-8,
PCI64-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1
M/S Certified
Configuration
P1 - Client LAN
P5 – Free or Local Storage
P6 - Shared Storage Controller
Booted from embedded SCSI
Storage
Local
Controller May use embedded SCSI, embedded DAC, NetRAID-1Si, or NetRAID-
3Si.
Driver For embedded SCSI, use sym_hi.version 4.12 or later. For embedded
DAC and NetRAID-xSi, use mraidnt.sys version 2.24.
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP.
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids Any
Shared
Controller
Model HP NetRAID-3Si Adapter D5955A
No. of controllers 1
Firmware W.01.30
BIOS B.02.02
Driver Mraidnt.sys 2.24
NetRAID Assistant A.01.15 or later
SCSI ID 6, 7
Channels 0, 1, 2
RAID level 1, 5, 10, 50
Logical disks 1 per RAID array, 8 maximum per NetRAID-3Si adapter
Configuration
options:
Cluster mode on
Cache write-policy to write-thru
Set any other options as you prefer