HP Netserver LP 2000r FC Config Guide for Windows NT4.0 Clusters
2
supply (UPS) using any power conditioner or UPS. Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version L.20.00 or later
Operating System
Service Pack
Microsoft Windows NT
Server 4.0, Enterprise Edition
SP6a or later
SPU
Model HP NetServer LP2000r
Clock speed 1 GHz
No. of CPUs 2
BIOS version 4.06.16 or later
CPU cache Any size
RAM 256 MB minimum. Must be HP.
Local storage See Local Storage below.
I/O slots Added cards may be installed in any appropriate slot, keeping in mind
the server's default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, PCI-1, PCI-2, PCI-3, Embedded SCSI
Microsoft
and HP
Certified
Configuration
P1 – Local storage (NetRAID-1M)
P2 –Shared Storage HBA (D8602B)
Booted from NetRAID-1M
Storage
Local
Controller May use embedded SCSI, NetRAID-1Si, NetRAID-3Si, NetRAID-1M,
or NetRAID-2M.
For SPOFless, recommend NetRAID-xM with internal drives in RAID-
5, or another fault-tolerant RAID level.
Driver For embedded SCSI, use SYM_U3.SYS version 5.05 or later.
For NetRAID-xSi, or
For NetRAID-xM, use MRAIDNT.SYS version 4.05 or later.
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP.
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids Any
Shared
HP Rack Storage/12FC (Required)
Host Bus Adapter
Model HP D8602B
No. of HBAs 1
Driver AFCNT4.SYS version 3.0.3245.1
RAID level 0, 1, 3, 5, 10