HP Netserver LPr FC Windows 2000 Config Guide for Windows 2000 Advanced Server Clusters

2
Power source Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.
System software:
Navigator version L.18.02 or later
Operating System Microsoft Windows 2000 Advanced Server
SPU
Model HP NetServer LPr
Clock speed 700, 800, 850 MHz
No. of CPUs 2
BIOS version 4.06.29.PR or later (700 MHz)
4.06.32 PR or later (800 MHz)
4.06.33 PR or later (850 MHz)
CPU cache Any size
RAM 256 MB minimum. Must be HP.
Local storage See Local Storage below.
I/O slots Added cards may be installed in any appropriate slot, keeping in mind
the server's default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, Embedded SCSI, PCI-3, PCI-2, PCI-1, PCI-4
M/S Certified
Configuration
P1 – Local storage (NetRAID-1Si)
P2 – Client LAN (D5013B)
P3 – Shared Storage FC HBA
P4 – Intra-cluster (Heartbeat) LAN (D5013B)
Booted from embedded SCSI in SPOF certification
Booted from NetRAID-1Si in SPOFless certification
Storage
Local
Controller May use embedded SCSI, NetRAID-1Si, or NetRAID-3Si.
For SPOFless, recommend NetRAID-xSi with drives in RAID-1 mirror,
or another fault-tolerant RAID level.
Driver For embedded SCSI, use sym_hi.sys from Windows 2000 Adv. Server
CD or later. For NetRAID-xSi, use mraid35x.sys version 2.62
(Navigator L.18.04.5 or later)
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives Must be HP (hot swap or fixed).
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids Any
Shared
HP Rack Storage/12FC Required - D5991A
Host Bus Adapter
Model HP Fibre Channel Host Bus Adapter - HP D8602A or D8602B
No. of controllers 1
Driver HP D8602A - Hhba5100.sys 2.06
HP D8602B - Afcw2k.sys 3.0.3245.1
RAID level 0, 1, 3, 5, 10