HP Netserver LPr FC Windows 2000 Config Guide for Windows 2000 Advanced Server Clusters

4
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
LANs
Intra-cluster (Heartbeat) LAN Client LAN
LAN connection HP D5954A crossover cable or
equivalent
Any LAN
The intra-cluster LAN may only be
used for cluster node communication
via a crossover cable or VLAN. It
may not be used for client
communication.
NIC:
Model HP D5013A/B (10/100TX PCI) Any that is on both the HP Tested
Products List and the Microsoft
Hardware Compatibility List.
For SPOFless, use D5013A or B
Driver Hptxnt5.sys 4.01.67 (supplied with
Microsoft Windows 2000 Advanced
Server CD) or later.
For SPOFless, use hptxnt5.sys
version 4.2.27.0 (Navigator
L.18.4.05) or later.
Vendor supported driver.
NOTE If the Client and Intra-
cluster LANs are the same model
(D5013A/B) the Client LAN
must use the same driver as the
Intra-cluster LAN.
No. of NICs 1 1
Shared Storage Cabling
This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer
LPr and one required HP Rack Storage/12FC and one or two optional HP Rack Storage/12s. Only these cabling
configurations and these cables are supported.