HP Netserver LPr NetRAID-3Si Installation Guide
2
SPU
Model HP NetServer LPr
Clock speed 400, 450, 500, 550, 600, 650, 700 MHz.
No. of CPUs 2
BIOS version 4.06.09 PR or later (400, 450 MHz with Rack Storage/12 D5989A)
4.06.14.PR or later (400, 450 MHz with Rack Storage/12 D5989B)
4.06.14.PR or later (500, 550 MHz with Rack Storage/12 D5989B)
4.06.29.PR or later (600, 650, 700 MHz with Rack Storage/12 D5989B)
CPU cache Any size
RAM 128 MB minimum. Must be HP.
Local storage See
Local Storage below.
I/O slots: P1 – Free or NetRAID Local storage
P2 - Client LAN
P3 – Shared storage controller
P4 -- Intra-cluster (Heartbeat) LAN
Storage
Local
Controller and Cabinets
(physical drive location)
May use embedded SCSI controller, NetRAID-1, NetRAID-3, NetRAID-
3Si in PCI slot P1.
May not use NetRAID-1Si.
Disk drives (hot swap
or fixed)
HP only
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI IDs Any
Shared
Controller
Model HP NetRAID 3Si Adapter D5955A
No. of controllers 1
Firmware W.01.20 or later
BIOS B.01.10 or later
Driver 2.22 or later
NetRAID Assistant A.01.15
SPU I/O slot P3
SCSI ID 6, 7
Channels 0, 1, 2
RAID level 1, 5, 10, 50
Logical disks 1 per RAID array
8 maximum per NetRAID adapter
Configuration
options:
Cluster mode on
Cache write-policy to Write thru
Set bus speed for Rack Storage/8 to Ultra
Set any other options as you prefer