distribution units (PDU’s) are strongly recommended.
System software:
Navigator version L.18.03 or later
Operating System Microsoft Windows NT Server 4.0, Enterprise Edition
Service pack SP6A or later
SPU
Model HP NetServer LT 6000r
Clock speed 550, 700 MHz
No. of CPUs 2 - 6
BIOS version 4.06.21 PW or later (550 MHz)
4.06.26 PW or later (700 MHz)
CPU cache Any size
RAM 128 MB minimum. Must be HP.
No. of power supplies 3 standard, 3 required for redundancy
Local storage See Local Storage below.
I/O slots: Added cards may be installed in any appropriate slot, keeping in mind the
server’s default boot order as listed below:
Default Boot Order IDE CD-ROM, FDD, Embedded A, Embedded B, PCI-6, PCI-5, PCI-4,
PCI-3, PCI-2, PCI-1
M/S Certified
Configuration
P2 - Client LAN
P4 – Local storage (NetRAID-1Si)
P6 –Shared Storage HBA
Booted from embedded DAC
Storage
Local
Controller May use embedded SCSI, embedded DAC, NetRAID-1Si or NetRAID-3Si.
Driver For embedded SCSI, use sym_hi.sys version 4.12 or later. For embedded
DAC and NetRAID-xSi, use mraidnt.sys version 2.24
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives Must be HP (hot swap or fixed)
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids Any
Shared
HP Rack
Storage/12FC
Required
Host Bus Adapter
Model HP Fibre Channel Host Bus Adapter - HP D8602A
No. of controllers 1
Driver Hhba5100.sys 1.12 or later
RAID level 0,1, 3, 5, 10
Cabinet HP NetServer Rack Storage/12FC- D5991A
RAID arrays Not more than eight physical drives per logical array and not more than
eight LUNs are permitted per cluster.