hp netserver lt 6000r netraid-4m config guide - for Microsoft NT 4.0 clusters PDF, 235K, 1/28/2002

lt6000rnt4m
1/28/02 2
Server Configuration
Parameter Specification
Number of power
supplies
Two standard, three required for redundancy
I/O slots Added cards may be installed in any appropriate slot, considering the server
default boot order provided below.
Default boot order IDE CD-ROM, FDD, embedded SCSI A, embedded SCSI B, PCI slot 6,
PCI slot 5, PCI slot 4, PCI slot 3, PCI slot 2, PCI slot 1
Local Storage
Controller Embedded SCSI, embedded DAC, NetRAID-1Si, NetRAID-3Si, NetRAID-1M,
or NetRAID-2M
Driver For embedded SCSI, sym_hi.sys, version 4.12.00, or later
For embedded DAC or NetRAID-1Si/3Si/1M/2M, mraidnt.sys, version 4.05,
or later
(all drivers obtained from Navigator CD-ROM, version L.20.00, or later)
Physical drive location Server internal drive bays, or HP external drive cabinet
(e.g., HP Rack Storage/12)
Disk drives Must be HP
SCSI bus Any HP cables that meet SCSI specifications, and any SCSI bus speed
SCSI IDs Any
System software
Navigator CD-ROM Ultra2 models Version L.20.00, or later
Ultra3 models Version M.04.00, or later
Operating system
Service pack
Microsoft Windows NT
Server 4.0 Enterprise Edition
SP6a
Power distribution
Layout Redundant power distribution units (PDUs) are recommended. See power cabling
diagram on page 6.
Shared Storage Configuration
Parameter Specification
Controller
Model HP NetRAID-4M Controller, Model D9161A, or D9351A
Number of controllers One or two
BIOS Disabled
Firmware Ultra2 models Build version 4584
(firmware obtained from Navigator CD-ROM, version L.20.00, or later)
Ultra3 models Build version 4607
(firmware obtained from Navigator CD-ROM, version M.04.00, or later)
Driver Ultra2 models Hpn.sys, version 2.4.0.4571, displayed in FAST as version 4571
(driver obtained from Navigator CD-ROM, version L.20.00, or later)
Ultra3 models Hpn.sys, version 2.4.0.4592, displayed in FAST as version 4592
(driver obtained from Navigator CD-ROM, version M.04.00, or later)