hp netserver lt 6000r netraid-4m config guide - for Microsoft NT 4.0 clusters PDF, 235K, 1/28/2002

lt6000rnt4m
1/28/02 3
Shared Storage Configuration
Parameter Specification
NetRAID-4M FAST Ultra2 models Version 2.4-0, or later
(software obtained from Navigator CD-ROM, version L.20.00, or later)
Ultra3 models Version 2.4-1, displayed in FAST as version 4605, or later
(software obtained from Navigator CD-ROM, version M.04.00, or later)
SCSI ID 6, 7
Channels 0, 1, 2, 3
RAID levels All fault-tolerant RAID types supported by controller: 1, 5, 10 (stripe set of
mirror sets RAID 0/1), 50 (stripe set of RAID-5 sets), volume set of mirror sets,
volume set of RAID-5 sets
Containers Single-level or multi-level
Must be fault-tolerant
Eight, maximum, per cluster
Configuration options Write cache disabled
Clustering enabled
Domain validation enabled
Enclosure
Disk drives Any HP drive supported by storage enclosure. Any combination of HP disk
models is allowed in a diskset, on a SCSI channel, or in a cluster.
Number of cabinets Up to eight
Model Rack Storage/12 D5989B, containing two D6025B SCSI controller cards, or
Rack Storage/12 D5989C, containing two D6025C SCSI controller cards
Status SCSI ID 5 (fixed)
Disk SCSI IDs 03, 815 (fixed)
Cables
SCSI Any two HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
See SCSI cabling diagram on page 5.
Power distribution
Layout Redundant power distribution units (PDUs) are recommended. See power cabling
diagram on page 6.
Microsoft
and HP Certified Server Configuration
Parameter Specification
I/O card slot PCI slot 5, NetRAID-4M shared storage controller
Network interfaces PCI slot 2, model D5013B, client LAN
Boot device Embedded DAC