hp netserver lxr 8500dc and xp config guide - Release DC.01.03 for four node Microsoft Windows 2000 Datacenter Server Clusters PDF, 29K, 11/9/2001
DC.01.03
11/9/01 3
Shared Storage Configuration
Parameter Specification
Cables
Optical HP shortwavelength 50/125 µm Fibre Channel optical cable
2 meter A3583A
16 meter A3531A
50 meter A3735A
100 meter A3736A
Power distribution
Layout Redundant power distribution units (PDUs) are recommended.
Microsoft
and HP Certified Server Configuration with NetRAID-1Si
Parameter Specification
Server
I/O card slot PCI slot 1, NetRAID-1Si local storage controller
PCI slot 2, Toptools Remote Control Card
PCI slot 9, FC HBA shared storage controller
Network interfaces PCI slot 6, D5013B intra-cluster (heartbeat) NIC
PCI slot 8, Intel Pro/1000T client LAN NIC
Boot device NetRAID-1Si
Microsoft
and HP Certified Server Configuration with NetRAID-1M
Parameter Specification
Server
I/O card slot PCI slot 2, Toptools Remote Control Card
PCI slot 3, NetRAID-1M local storage controller
PCI slot 9, FC HBA shared storage controller
Network interfaces PCI slot 5, Emulex Giganet cLAN 1000 client LAN NIC
PCI slot 6, D5013B intra-cluster (heartbeat) NIC
Boot device NetRAID-1M
Microsoft
and HP Certified Server Configuration with NetRAID-4M
Parameter Specification
Server
I/O card slot PCI slot 2, Toptools Remote Control Card
PCI slot 7, NetRAID-4M local storage controller
PCI slot 9, FC HBA shared storage controller
Network interfaces PCI slot 5, Emulex Giganet cLAN 1000 client LAN NIC
PCI slot 6, D5013B intra-cluster (heartbeat) NIC
Boot device NetRAID-4M