HP Netserver Remote Administrator Guide

77
A Event Codes
The table below describes the event codes that can be sent via pager or listed in
the event log. When Integrated RA sends a page about a server event, it includes
the server identifying number and a five-digit code identifying the event. (If you
have a TAP pager, you will receive the server name and some descriptive text as
well.)
Note that NetServer Agents software will need to be loaded on your server in
order to receive an event notification for most of the events listed below. Refer to
the HP NetServer SNMP agents documentation (viewable via the NetServer
Documentation CD) for agent installation and configuration instructions. Refer to
the Readme file for Agents software located on the Navigator CD under
manage\server.
NOTE It's a good idea to copy appropriate sections of this table and
keep it with the pager you use to receive notifications. A
regularly updated list of HP supported event codes is available
via the WWW at http://www.hp.com/netserver under the
Troubleshooting section under Technical Support.
Notification and log messages are limited to a length of 40 characters.
Pager Code Server Event Severity
001XX
Temperature sensor crossed lower non-critical threshold WARNING
001XX
Temperature sensor crossed lower critical threshold CRITICAL
001XX
Temperature sensor crossed lower non-recoverable threshold CRITICAL
001XX
A temperature inside the server has gone outside the factory specified
range.
WARNING
001XX
A temperature inside the server has gone far outside the factory
specified range.
CRITICAL
001XX
Temperature sensor crossed upper non-recoverable threshold CRITICAL
002XX
A measured voltage in the server has gone outside the factory
specified lower voltage range.
WARNING
002XX
A measured voltage in the server has gone far outside the factory
specified lower voltage range.
CRITICAL
002XX
Voltage sensor crossed lower non-recoverable threshold CRITICAL
002XX
A measured voltage in the server has gone outside the factory
specified upper voltage range.
WARNING
002XX
A measured voltage in the server has gone far outside the factory
specified upper voltage range.
CRITICAL
002XX
Voltage sensor crossed upper non-recoverable threshold CRITICAL
002XX
System Voltage failure WARNING
004XX
A fan sensor in the server has gone outside the factory specified WARNING