HP Netserver Remote Administrator Guide
Appendix A Event Codes
78
Pager Code Server Event Severity
range.
004XX
A fan sensor in the server has gone far outside the factory specified
range.
CRITICAL
004XX
Fan sensor crossed lower non-recoverable threshold CRITICAL
004XX
Fan sensor crossed upper non-critical threshold WARNING
004XX
Fan sensor crossed upper critical threshold CRITICAL
004XX
Fan sensor crossed upper non-recoverable threshold CRITICAL
004XX
Two or more of the fans in the Processor/PCI Fan Tray have stopped
or have been removed.
CRITICAL
004XX
Fan problem in Processor/PCI Fan Tray has been corrected. INFORMATIONAL
004XX
Two or more of the fans in the Memory Fan Tray have stopped or
been removed.
CRITICAL
004XX
Fan problem in the Memory Fan Tray has been corrected. INFORMATIONAL
004XX
One of the fans in the Memory Fan Tray stopped. CRITICAL
004XX
One of the fans in the Processor/PCI fan tray stopped. CRITICAL
00520
I/O area open WARNING
00530
The server's built-in sensors have detected an open chassis door. WARNING
00530
Processor area open WARNING
00600
Front Panel Button Violation INFORMATIONAL
00701
Processor module is operating outside of acceptable margins WARNING
00700
Processor internal error CRITICAL
00701
Processor Thermal Trip Failure CRITICAL
00702
Processor failed internal self test CRITICAL
00703
Processor hung during POST CRITICAL
00704
Processor startup/initialization failed CRITICAL
00705
Configuration Error in a Processor Slot CRITICAL
00707
Processor failure CRITICAL
00708
Processor (#) Disabled CRITICAL
00709
Processor or Terminator was not detected CRITICAL
00717
Processor problem CRITICAL
00718
The Processor in the indicated slot has been disabled by the BIOS. CRITICAL
00719
A single or multiple ECC Error has been detected on the P6 bus. WARNING
00720
The Processor Card is missing or not properly terminated in indicated
processor module.
WARNING
00721
Voltage Regulating Module (VRM) on the indicated processor
module had failed.
CRITICAL
00800
Indicated Power Supply has been removed. WARNING
00800
The indicated Power Supply has been inserted. INFORMATIONAL
00801
Power supply unit power has failed. WARNING
00802
Predictive failure/alert in Power supply WARNING
00816
Redundant Power Supply: Subsystem warning temperature exceeded WARNING
00817
Temperature alert on designated Power Supply. CRITICAL
00818
Redundant Power Supply: AC power source failure CRITICAL
00819
Redundant Power Supply: Protection temperature exceeded, DC
shutdown
CRITICAL
00820
Redundant Power Supply: Protection temperature normal, power
restored
INFORMATIONAL
00821
Fan failure on designated Power Supply. CRITICAL
00822
Fan speed-up on designated Power Supply. WARNING