Appendix A Event Codes
86
Pager Code Server Event Severity
21520
Uninterrupted Power Supply: UPS is on bypass due to hardware
failure
CRITICAL
21521
Uninterrupted Power Supply: UPS put on bypass via software or
front panel
WARNING
21522
Uninterrupted Power Supply: UPS put on bypass via rear UPS switch WARNING
21523
Uninterrupted Power Supply: UPS has returned from bypass mode INFORMATIONAL
21524
Uninterrupted Power Supply: Base module bypass power supply
needs repair
CRITICAL
21525
Uninterrupted Power Supply: Base module fan needs repair CRITICAL
21526
Uninterrupted Power Supply: Communication lost with external
battery packs
WARNING
21527
Uninterrupted Power Supply: Communication established with
external battery packs
INFORMATIONAL
21528
Uninterrupted Power Supply: Battery run-time calibration test
initiated
INFORMATIONAL
21600
The NetWare Loadable Module (NLM) that detects SCSI faults has
been unloaded.
INFORMATIONAL
21605
An installed host adapter can no longer be detected. CRITICAL
21606
An installed SCSI device can no longer be detected. CRITICAL
21608
A new host adapter has been discovered. INFORMATIONAL
21609
An installed host adapter no longer matches the information stored
about it.
INFORMATIONAL
21610
An installed host adapter can no longer be detected. CRITICAL
21611
A host adapter that previously failed is now accessible. NORMAL
21612
An installed SCSI device can no longer be detected. CRITICAL
21613
A new SCSI device, such as a CD-ROM drive, hard drive or tape
drive, has been detected.
INFORMATIONAL
21614
An installed SCSI device that previously failed is now accessible. NORMAL
21615
An installed SCSI device no longer matches the information stored
about it.
INFORMATIONAL
21625
The SCSI monitoring software on the server has determined that the
device database is corrupt.
CRITICAL
21816
An unrecognized HW log event was detected. INFORMATIONAL
21900
FCArray: A physical device became online. INFORMATIONAL
21901
FCArray: A hard disk has been added as a hot spare. INFORMATIONAL
21902
FCArray: Hard disk error found. CRITICAL
21903
FCArray: Hard disk PFA condition found, drive may fail. WARNING
21904
FCArray: An automatic rebuild has started. INFORMATIONAL
21905
FCArray: A manual rebuild has started. INFORMATIONAL
21906
FCArray: Rebuild completed. INFORMATIONAL
21907
FCArray: Rebuild cancelled. INFORMATIONAL
21908
FCArray: Rebuild stopped with errors. CRITICAL
21909
FCArray: Rebuild failed due to new physical device. CRITICAL
21910
FCArray: Rebuild failed due to logical device failure. CRITICAL
21911
FCArray: A physical device failed. CRITICAL
21912
FCArray: A physical device was found. INFORMATIONAL
21913
FCArray: A physical device is gone. INFORMATIONAL
21914
FCArray: A physical device is unconfigured. INFORMATIONAL
21915
FCArray: Expand capacity started. INFORMATIONAL
21916
FCArray: Expand capacity finished. INFORMATIONAL