HP Netserver Service Handbook, Volume 3 - High-End

28
Left upper hot swap drive cage switch settings and SCSI ID numbers
Switch Position Hot Swap Drive Shelf
1 2 3 4 5 6 1 2 3
off off off off on off ID=1 ID=2 ID=3
off off off on on off ID=1 ID=0 ID=3
off off on off on off ID=9 ID=10 ID=11
off off on on on off ID=9 ID=8 ID=11
Left lower hot swap drive cage switch settings and SCSI ID numbers
Switch Position Hot Swap Drive Shelf
1 2 3 4 5 6 4 5 6
off off off off on on ID=4 ID=5 ID=6
off off off on on on ID=4 ID=0 ID=6
off off on off on on ID=12 ID=13 ID=14
off off on on on on ID=12 ID=8 ID=14
Specifications
Temperature
Operating
5° to 35° C (41° to 95° F)
Non-operating
–40° to +70° C (–40° to +158° F)
Humidity (noncondensing)
Operating
20% to 80% relative humidity
Non-operating
90% relative humidity
Altitude
Operating
3,046 m (10,000 ft)
Non-operating
12,200 m (40,000 ft)
Maximum Air Conditioning Load
LX Pro Less than 1058 KCal (4200 BTU)
LXe Pro 110V: 1032 KCal/Hour (4100 BTU/Hour)
220V: 1234 KCal/Hour (4900 BTU/Hour)
Minimum Clearance
Front
1m (39 in)
Back
15 cm (6 in) ventilated space
Weight and Dimensions
With Casters Without Casters
Height
630 mm (24.57 in) 570 mm (22.23 in)