hp netserver lc 2000 netraid-2m config guide - for Microsoft Windows 2000 A.S. Clusters PDF, 209K, 8/13/2001

LC20002K2M
8/13/01 2
Server Configuration
Parameter Specification
I/O slots Added cards may be installed in any appropriate slot, considering the server
default boot order provided below.
Default boot order
IDE CD-ROM, FDD, SCSI A, SCSI B, PCI-1, PCI-2, PCI-3, PCI-4, PCI64-5,
PCI64-6
Local Storage
Controller Embedded SCSI, NetRAID-1M, or
NetRAID-2M (in addition to shared storage NetRAID-2M controller)
Driver For embedded SCSI, sym_u3.sys, version 5.07.00, or later
For NetRAID-1M or NetRAID-2M, mraid2k.sys, version 5.20, or later
(all drivers obtained from Navigator CD-ROM, version L.20.00, or later)
Physical drive location Server internal drive bays, or HP external drive cabinet
(e.g., HP Rack Storage/12)
Disk drives Must be HP
SCSI bus Any HP cables that meet SCSI specifications, and any SCSI bus speed
SCSI IDs Any
System software
Navigator CD-ROM Version M.04.00, or later
Operating system
Service pack
Microsoft Windows
2000 Advanced Server
SP1
Power distribution
Layout Redundant power distribution units (PDUs) are recommended. See power
cabling diagram on page 6.
Shared Storage Configuration
Parameter Specification
Controller
Model HP NetRAID-2M Controller, Model P3411A, or P3475A
Number of controllers One or two
BIOS Disabled
Firmware Version H.01.08
(firmware obtained from Navigator CD-ROM, version M.04.00, or later)
Driver mraid2k.sys, version 5.20
(driver obtained from Navigator CD-ROM, version L.20.00, or later)
NetRAID Assistant Version B.01.04, or later
(software obtained from Navigator CD-ROM, version L.20.00, or later)
SCSI ID 6, 7
Channels 0, 1
RAID levels 1, 5, 10, 50
Logical disks One per RAID array
Eight, maximum, per cluster
Configuration options Cluster mode on
Cache write policy to Write thru