HP Netserver LH 4 Rack Storage/12FC Cluster Config Guide for Windows NT4.0 Clusters

2
Operating system
Service pack
Microsoft Windows NT Server 4.0, Enterprise Edition
SP6a or later
SPU
Model HP NetServer LH4
Clock speed 400, 450, 500, 550, 700 MHz
No. of CPUs 2 – 4
BIOS version 4.06.22 PS or later (400 – 550 MHz)
4.06.32 PS or later (700 MHz)
CPU cache Any size
RAM 128 MB minimum. Must be HP.
No. of power supplies 3 required, 4 for redundancy
Local storage See
Local Storage below.
I/O slots Added cards may be installed in any appropriate slot, keeping in mind
the server’s default boot order as listed below:
Default Boot Order IDE CD-ROM, FDD, Embedded A, Embedded B, PCI-1, PCI-2, PCI-3,
PCI-4, PCI-5, PCI-6, PCI-7, PCI-8
M/S Certified
Configuration
P1 – Shared storage FC HBA (D8602A)
P3 – Client LAN (D5013B)
P4 – Intra-cluster (Heartbeat) LAN (D5013B)
P7 – Local storage (NetRAID-1Si)
Storage
Local
Controller May use embedded SCSI, embedded DAC, NetRAID-3Si or
NetRAID-1Si.
Drivers For embedded SCSI, use sym_hi.version 4.12 or later. For embedded
DAC and NetRAID-xSi, use mraidnt.sys version 2.24.
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP.
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids Any
Shared
HP Rack Storage/12FC Required
Host Bus Adapter
Model HP D8602A
No. of HBAs 1
Driver Hhba5100.sys 1.12 or later
RAID level 0, 1, 3, 5
Cabinet
RAID arrays Not more than 8 physical drives per logical array and not more than 8
LUNs are permitted per Rack Storage/12FC and Rack Storage/12
combination in a cluster.
No. of cabinets 1
FC Array Cards