HP Netserver LP 1000r FC Config Guide for Windows NT4.0 Clusters

2
System software:
Navigator version L.20.00 or later
Operating System
Service Pack
Microsoft Windows NT
4.0
SP6a or later
SPU
Model HP NetServer LP1000r
Clock speed 1 GHz
No. of CPUs 2
BIOS version 4.06.12 or later
CPU cache Any size
RAM 256 MB minimum. Must be HP.
Local storage See Local Storage below.
Microsoft
and HP
Certified
Configuration
P1 – Shared Storage FC HBA (D8602A)
Booted from Embedded SCSI
Storage
Local
Controller Embedded SCSI
Driver
SYM_U3.SYS Version 5.05.00 or later (Navigator L.20.00 or later).
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives Must be HP (hot swap or fixed).
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids Any
Shared
HP Rack Storage/12FC Required - D5991A
Host Bus Adapter
Model HP Fibre Channel Host Bus Adapter - HP D8602A
No. of controllers 1
Driver HP D8602A - Hhba5100.sys Version 2.06
RAID level 0, 1, 3, 5, 10
For SPOFless configurations a fault tolerant RAID type, e.g. RAID 5, is
recommended for all shared storage.
Cabinet HP Rack Storage 12/FC – D5991A
RAID arrays Not more than 8 physical drives per logical array and not more than 8
LUNs are permitted per cluster.
No. of cabinets 1
FC Array Cards
Model HP Fibre Channel Array Controller - D5990A
No. of cards/cabinet 2 (Requires second card be installed in the Rack Storage/12FC.)
Firmware 4.64-00 or later
5.46-04