HP Netserver LP 1000r FC Config Guide for Windows NT4.0 Clusters
3
FC Array Assistant A.002-5
Status SCSI ID 5 (fixed)
Disk SCSI IDs 0 – 3, 8 – 15 (fixed)
Disk drives: Any HP drive supported by storage enclosure
Fibre-channel cables Optical (Server to Hub only):
50 meter D6980A
100 meter D6981A
Copper (Shared Storage to Hub and Server to Hub ):
3 meter D6978A
5 meter D6979A
10 meter D7080A
Hub
Model HP D6976A 6-port fibre channel
Or HP P4459A 8-port switch
Quantity 1 for SPOF
2 for SPOFless with hubs
HP Rack Storage/12 Optional
Number of cabinets: 1 – 2
Model HP Rack Storage/12 – D5989B or C plus two D6025B or two D6025C
SCSI cards for each cabinet
Status SCSI ID 5 (fixed)
Disk SCSI IDs 0 – 3, 8 – 15 (fixed)
Disk drives: Same as HP Rack Storage/12FC
Cables Any HP LVD SCSI cables from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
LANs
Intra-cluster (Heartbeat) LAN Client LAN
LAN connection HP D5954A crossover cable or
equivalent
Any LAN
The intra-cluster LAN may only be
used for cluster node communication
via a crossover cable or VLAN. It
may not be used for client
communication.
NIC:
Model Embedded Any that is on both the HP Tested
Products List and the Microsoft
Hardware Compatibility List.
Driver Hptxnt.sys 4.02.30 or later Vendor supported driver.
No. of NICs 1 1