hp netserver lxr 8500dc and xp config guide - Release DC.02.00 for four node Microsoft Windows 2000 Datacenter Server Clusters PDF, 28K, 2/25/2002

DC.02.00
2/25/02 2
Server Configuration
Parameter Specification
Number of power
supplies
Three
Local Storage
Controller For new customers,
HP NetRAID-1M Controller, Model P3410A, BIOS G.01.02, Firmware H.01.08
HP NetRAID-4M Controller, Model D9351A, BIOS Build 2.4-1, Firmware 4607,
NetRAID-4M FAST utility version 4605
For existing customers,
HP NetRAID-1Si Controller, Model D2140A, BIOS B.02.02, Firmware F.02.04
Driver For NetRAID-1M, mraid2k.sys, version 5.20
For NetRAID-4M, hpn.sys, version 2.4.0.4605
For NetRAID-1Si, mraid35x.sys, version 2.62
Physical drive location Server internal drive bays
Disk drives Must be HP
SCSI bus Any HP cables that meet SCSI specifications, and any SCSI bus speed
SCSI IDs Any
System software
Distribution media DC.02.00
Operating system Microsoft Windows
2000 Datacenter Server with Service Pack 2
and Security Update Q301625.
Update patch is located at the URL below:
http://support.microsoft.com/directory/article.asp?ID=KB;EN-US;q301625
Application software
Microsoft Exchange 2000 Server, with Exchange 2000 Service Pack 1
HP Surestore Auto Path XP for Windows 2000, version 1.03.02,
HP Product B9500A, for media, and B9502A for five licenses
(or the B9500A and one B9501A, a single license, for each LXr 8500dc server)
Power distribution
Layout Redundant power distribution units (PDUs) are recommended.
Shared Storage Configuration
Parameter Specification
Controller
Model HP Fibre Channel host bus adapter (HBA), Model D8602B
Bus Protocol Fabric / Nport
Number of controllers One or two per server
Driver Afcw2k.sys, version 3.0.4107.0
Enclosure
HP Surestore E Disk Array XP256, XP512, or XP48
Disk drives Must be HP.
Number of cabinets One or more
Firmware versions
XP256
XP512
XP48
52.48.61.00/00
01.15.38.00/05
01.15.38.00/05
Support (.inf) file version
5.00.2195.3