2/25/02 3
Shared Storage Configuration
Parameter Specification
FC Switches
Brocade Silkworm 2400/2800, HP Models A5625A/A5624A,
Firmware version a.2.4.1
Cables
Optical HP short wavelength 50/125 µm Fibre Channel optical cable
2 meter A3583A
16 meter A3531A
50 meter A3735A
100 meter A3736A
Power distribution
Layout Redundant power distribution units (PDUs) are recommended.
Microsoft
and HP Certified Server Configuration
Parameter Specification
Server
I/O card slot PCI slot 1, NetRAID-1Si local storage controller
PCI slot 2, HP Toptools Remote Control card
PCI slots 7 & 9, FC HBA shared storage controllers
Network interfaces PCI slot 6, D5013B intra-cluster (heartbeat) NIC
PCI slot 8, Intel
Pro/1000T client LAN NIC
Boot device NetRAID-1Si
Intra-Cluster (Heartbeat) LAN Configuration
Parameter Specification
Network
Connection Any HP ProCurve switch, or equivalent.
The intra-cluster LAN may only be used for cluster node communication. It may
not be used for client communication.
NIC
Quantity One
Model One of the following:
HP 10/100TX PCI, Model D5013B
Intel
Pro/1000T (copper), Model PWLA8490T
Intel
Pro/1000F (fiber optical), Model PWLA8490SX
Emulex
Giganet/cLAN 1000 (copper), Model cLAN 1000
Driver
HP Model D5013B Version 5.40.17
Intel
Model PWLA8490T Version 2.84.284.0
Intel
Model PWLA8490SX Version 2.84.284.0
Emulex
Model cLAN 1000 Version 4.1.1