HP Netserver LXr Pro Surestore E Installation Guide
HP NetServer Installation Guide 29
• First, load the driver for the device you want to boot from. For drives in the LH 4 internal bays this
will normally be the embedded SCSI Symbios driver or embedded NetRAID.
• Secondly, load the IDE driver, since the CD drive is on the IDE bus.
• Finally, load any other mass storage drivers you need. If you are using the Fibre Channel HBA for
shared storage do not load the HP Fibre Channel driver at this time. It will be loaded later.
3. Continue the installation using floppy disks#2 and #3 and select the following options when prompted:
• Choose the unpartitioned space and install Windows NT.
• Choose NTFS file system
• When prompted to search for a Network Adapter, load NIC drivers for both the intra-cluster and the
client LAN. Be sure to load the correct intra-cluster LAN driver version as specified in the
Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice,
once for the intra-cluster NIC and once for the client NIC.
• Make sure TCP/IP Protocol is selected.
Other protocols may be selected in addition, but TCP/IP is required.
• If you are using two HP D5013A NICs, when prompted for TCP/IP Properties:
Make sure adapter [2] is highlighted and specify its IP address and subnet mask. This will be the
LAN adapter for the intra-cluster LAN.
Select adapter [1] and specify its IP address and subnet mask. This will be the LAN adapter for the
client LAN.
Set TCP/IP Properties for DNS, WINS Address, etc. at this time.
NOTE The Client LAN IP addresses and Intra-cluster LAN IP addresses must be on different
subnets.
4. Once the NT installation is complete, the D5013A NIC drivers must be manually set to the correct LAN
speed. Log on and from the start menu select: Settings, Control Panel, Network, and
Adapters. For each D5013A adapter, select Properties then Settings and set the network
speed to the appropriate setting (either 10 Mbps or 100 Mbps) for your network. The intra-cluster LAN
should be set to 100 Mbps. Do not use the Auto setting.
Part "6 Shared Storage Software Setup" in the Shared Storage Supplement and start with
Install Fibre Channel HBA Driver.
Install Service Pack for All HP NetServers
Refer to the Configuration Guide for your cluster configuration and install the applicable Microsoft Service
Pack (SP3 or SP4). Do not install the Hot Fix associated with Service Pack 3 at this time.
NOTE Do not install the Microsoft Cluster Server Software (MSCS) at this time.
NOTE After completing these procedures, power down System B and power up System A.
Repeat all of the procedures in this part for System A.