HP Netserver LH 6000 NetRAID-4M Config Guide for Windows NT4.0 Clusters

2
supply (UPS) using any power conditioner or UPS. Redundant power
distribution units (PDUs) are strongly recommended.
System software:
Navigator version M.02.00 or later
Operating System
Service Pack
Microsoft Windows NT
Server 4.0 Enterprise Edition
SP6a
SPU
Model HP Netserver LH 6000
Clock speed 900 MHz
No. of CPUs 2 - 6
BIOS version 4.06.38 PU or later
CPU cache Any size
RAM 128 MB minimum. Must be HP.
No. of power supplies 3 standard, 4 required for redundancy
Local storage See Local Storage below.
I/O slots Added cards may be installed in any appropriate slot, keeping in mind the
servers default boot order as listed below:
Default Boot Order IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI64-8,
PCI64-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1
Microsoft
and HP
Certified
Configuration
P1 – Client LAN – D5013B
P7– Shared Storage – NetRAID-4M
Booted from Embedded DAC
Storage
Local
Controller May use embedded SCSI, embedded DAC, NetRAID-1Si, NetRAID-3Si,
NetRAID-1M or NetRAID-2M.
Driver For embedded SCSI, use sym_hi.sys 4.12 or later.
For Embedded DAC or NetRAID-xSi, use mraidnt.sys version 4.05
For NetRAID-1M/2M, use mraidnt.sys, version 4.05 or later.
All are from Navigator L.20.00 or later.
Physical drive location SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12)
Disk drives Must be HP
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed
SCSI Ids Any
Shared
Controller
Model HP NetRAID-4M Adapter D9161A or D9351A
No. of controllers 2
BIOS
Disabled
Firmware 4584
Driver Hpn.sys version 2.4.0.4571
NetRAID-4M FAST 2.4-0 or later
SCSI ID 6, 7