HP Netserver DiagTools v2.0 User Guide

Chapter 5 Error Message Reference
39
Code Description Recommended Action
5. Check the seating of the voltage regulator module (VRM) if present.
6. Be sure the processor board (if any) is seated.
7. Make sure the CPU chip is seated. (Take ESD precautions.)
8. Make sure the memory elements (DIMMs) are properly seated.
9. Check system fans. If overheating occurs, chip may shut down.
10. If the system ran with temperature high, let it cool for 30 minutes, then
restart.
11. If system repeatedly shows this error, replace the element with the CMOS.
00C0h DiagTools Error Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.
00C1h DiagTools Error Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.
00C2h DiagTools Error Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.
00C3h MMX Regs.
Read/Write failed.
1. Take ESD precautions and make sure the system board is seated.
2. Check the seating of the voltage regulator module (VRM) if present.
3. Be sure the processor board (if any) is seated.
4. Make sure the CPU chip is seated.
5. Make sure the memory elements (DIMMs) are properly seated.
6. Check system fans. If overheating occurs, chip may shut down.
7. If the system ran with temperature high, let it cool for 30 minutes, then restart.
8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
00C4h Wraparound
Arithmetic test
failed
1. Take ESD precautions and make sure the system board is seated.
2. Check the seating of the voltage regulator module (VRM) if present.
3. Be sure the processor board (if any) is seated.
4. Make sure the CPU chip is seated.
5. Make sure the memory elements (DIMMs) are properly seated.
6. Check system fans. If overheating occurs, chip may shut down.
7. If the system ran with temperature high, let it cool for 30 minutes, then restart.
8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
00C5h Saturation
Arithmetic test
failed.
1. Take ESD precautions and make sure the system board is seated.
2. Check the seating of the voltage regulator module (VRM) if present.
3. Be sure the processor board (if any) is seated.
4. Make sure the CPU chip is seated.
5. Make sure the memory elements (DIMMs) are properly seated.
6. Check system fans. If overheating occurs, chip may shut down.
7. If the system ran with temperature high, let it cool for 30 minutes, then restart.
8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
00C6h Pack with signed
saturation failed.
1. Take ESD precautions and make sure the system board is seated.
2. Check the seating of the voltage regulator module (VRM) if present.