HP Netserver DiagTools v2.0 User Guide

Chapter 5 Error Message Reference
46
Code Description Recommended Action
4. Make sure the CPU chip is seated.
5. Make sure the memory elements (DIMMs) are properly seated.
6. Check system fans. If overheating occurs, chip may shut down.
7. If the system ran with temperature high, let it cool for 30 minutes, then
restart.
8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
01A2h TagRAM Control
Register Test Failed.
1. Take ESD precautions and make sure the system board is seated.
2. Check the seating of the voltage regulator module (VRM) if present.
3. Be sure the processor board (if any) is seated.
4. Make sure the CPU chip is seated.
5. Make sure the memory elements (DIMMs) are properly seated.
6. Check system fans. If overheating occurs, chip may shut down.
7. If the system ran with temperature high, let it cool for 30 minutes, then
restart.
8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
01A4h L2 cache Commands
Test Failed.
1. Take ESD precautions and make sure the system board is seated.
2. Check the seating of the voltage regulator module (VRM) if present.
3. Be sure the processor board (if any) is seated.
4. Make sure the CPU chip is seated.
5. Check system fans. If overheating occurs, chip may shut down.
6. If the system ran with temperature high, let it cool for 30 minutes, then
restart.
7. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
01A3h L2 cache Commands
Test Failed.
1. Take ESD precautions and make sure the system board is seated.
2. Check the seating of the voltage regulator module (VRM) if present.
3. Be sure the processor board (if any) is seated.
4. Make sure the CPU chip is seated.
5. Make sure the memory elements (DIMMs) are properly seated.
6. Check system fans. If overheating occurs, chip may shut down.
7. If the system ran with temperature high, let it cool for 30 minutes, then
restart.
8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
FDD (Flexible Disk Drive or Floppy) Tests
Flexible Disk Drives are tested for rotational speed, elevator, and seek channel.
Code Description Recommended Action
0301h Undefined or
invalid command.
1. Try a different diskette.
2. Check the cable between the floppy drive and the system board.
3. Change the floppy drive.