HP Netserver DiagTools v2.0 User Guide

Chapter 5 Error Message Reference
51
Code Description Recommended Action
3. Check seating of board or SCSI card.
4. Check for proper termination, using technical reference card or label.
5. Check system fans
6. Check firmware version of drive and update if necessary.
7. Replace the drive
8. Change the card or board that has the drive’s controller.
0503h SCSI disk read timed
out.
1. Check cables and connections: a) to SCSI components, b) to power source, c)
between cards and backplane.
2. Inspect SCSI pins to ensure none are bent.
3. Check seating of board or SCSI card.
4. Check for proper termination, using technical reference card or label.
5. Check system fans
6. Check firmware version of drive and update if necessary.
7. Replace the drive
8. Change the card or board that has the drive’s controller.
0504h DiagTools Error Download a new version of DiagTools from the HP web site and run it. If you
get the same error, call the HP Customer Care Center.
0505h DiagTools Error Download a new version of DiagTools from the HP web site and run it. If you
get the same error, call the HP Customer Care Center.
0506h DiagTools Error Download a new version of DiagTools from the HP web site and run it. If you
get the same error, call the HP Customer Care Center.
0507h SCSI disk buffer
error.
1. Check cables and connections: a) to SCSI components, b) to power source, c)
between cards and backplane.
2. Inspect SCSI pins to ensure none are bent.
3. Check seating of board or SCSI card.
4. Check for proper termination, using technical reference card or label.
5. Check system fans
6. Check firmware version of drive and update if necessary.
7. Replace the drive
8. Change the card or board that has the drive’s controller.
0508h SCSI disk random
read error.
1. Check cables and connections: a) to SCSI components, b) to power source, c)
between cards and backplane.
2. Inspect SCSI pins to ensure none are bent.
3. Check seating of board or SCSI card.
4. Check for proper termination, using technical reference card or label.
5. Check system fans
6. Check firmware version of drive and update if necessary.
7. Replace the drive
8. Change the card or board that has the drive’s controller.
0509h DiagTools Error Download a new version of DiagTools from the HP web site and run it. If you
get the same error, call the HP Customer Care Center.
050Ah DiagTools Error Download a new version of DiagTools from the HP web site and run it. If you