Installation and configuration of the HP NetRAID, NetRAID-1 and NetRAID 3Si Adapters

119
11 Troubleshooting
Power-up (Boot) Error Messages
Adapter BIOS Disabled. No Logical Drives Handled by BIOS
Problem: The adapter BIOS is disabled. (This is not a problem if the BIOS is
intentionally disabled to prevent booting from the adapter.)
Suggested solution: Enable the BIOS by using HP NetRAID Express Tools, as
described in "Run Configuration Utilities" in Chapter 6.
Host Adapter at Baseport
xxxxh
not Responding
Problem: The BIOS cannot communicate with the firmware on the adapter.
Suggested solutions:
• Verify that the adapter card is plugged all the way into its slot.
• Moving the adapter card to another slot.
• Run diagnostics under HP NetRAID Express Tools to verify that the
adapter card is functioning properly.
No HP NetRAID Adapter
Problem: The BIOS cannot communicate with the firmware on the adapter.
Suggested solutions:
• Verify that the adapter card is plugged all the way into its slot.
• Try moving the adapter card to another slot.
• Run diagnostics under HP NetRAID Express Tools to verify that the
adapter card is functioning properly.
Configuration of NVRAM and drives mismatch
Run View/Add Configuration option of Configuration Utility.
Press any key to enter the Configuration Utility.
Problem: There is a single adapter, and the configuration stored in its NVRAM
does not match the configuration stored in the drives.