HP NetServer LH 3/LH 3r Quick Service Reference Guide Last Updated: June 1999
Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
HP NetServer LH 3 and LH 3r System Information Front Control Panel Control Description Lock (LH 3 only) Locks system to prevent unauthorized use. DC Power Switchand indicator light Turns the NetServer on and off. This switch is behind the protective door on the front panel. Push once to turn on, again to turn off. (To disconnect the NetServer from AC power, remove the AC power cord from the power supply cage on the rear.) RESET 1 Resets the NetServer from internal ROM.
Keyboard lockand indicator light unauthorized use. Locks system keyboard to prevent Status screen Reports various types of system status. The buttons below the screen control these menu functions Return to a previous selection. Select a menu item. Reserved for future use. Scroll down or up.
Removing the Covers (LH 3X) Cover 1 Cover 2 Cover 3 Cover 2 Cover 3 Cover 1 Removing the Covers (LH 3r) Cover 1 Cover 2 Cover 3 Memory There are four DIMM sockets on the system board for memory expansion. You can use 64 MB, 128 MB, and 256 MB DIMMs for a maximum capacity of 1 GB of RAM. • The minimum memory configuration for the NetServer LH 3/LH 3r is one 128 MB DIMM. • The system board DIMM sockets are numbered from 0 to 3.
Boot Device Priority Slot 1 16-bit ISA or 32-bit PCI Slot 2 32-bit PCI Slot 3 32-bit PCI Slot 4 32-bit PCI Slot 5 32-bit PCI Slot 6 32-bit PCI Slot 7 32-bit PCI Slot 8 32-bit PCI Boot order for PCI controllers is determined by slot location. The system searches for a bootable device in the following order: 1. IDE CD-ROM drive with a bootable CD-ROM. 2. Flexible disk drive with a bootable flexible disk. 3. Embedded SCSI controller or embedded DAC. 4.
Processor or Terminator Board Not Installed Install processor in primary processor socket and a processor or terminator board in secondary processor socket.
30 1 4 6 5 7 3 2 28 31 32 27 26 29 6
42 43 41 44 34 38 40 14 41 39 HP NetServer Replaceable Parts List Fig Description Replacement Exchange 1 System board PCA D5000-60001 D5000-69000 2 I/O PCA 5064-1996 D5000-69001 3 Backplane PCA 5064-1997 5a Pentium II 350mhz processor 1821-4201 5b Pentium II 400mhz processor 1821-4202 * Heat sink for processor module 5183-2471 * Heat sink clip 5183-2472 4 Terminator PCA ( plugs in secondary processor slot in dual-ready systems) 5183-3418 6 Voltage Regulator Module (VRM)
17a Non-hot-swap tray, hard disk drive (3 ea.) D2198B 17b Non-hot-swap tray, removable media device (2 ea.) D2199A 18a 4.2 GB Ultra/Wide SCSI drive, 7200 rpm (for non-hotswap use) D4910A 18b 9.1 GB Ultra/Wide SCSI drive, 7200 rpm (for non-hotswap use) D4911A 18c 9.1 GB low-profile Ultra2 drive, 7200 rpm (for hot-swap use) D6106A 18d 9.1 GB low-profile Ultra2 drive, 10,000 rpm (for hot-swap use) D6107A 18e 18.2 GB half-height Ultra2 drive, 7200 rpm (for hot-swap use) D6108A 19 1.44MB 3.
Keyboards Language Part Number Language Part Number US D4950-63001 Danish D4950-63016 Arab/French D4950-63025 Fr.
System Board Illustration System Switches 10
Specifications Operating Temperature 5°to 35°C (41°to 95°F) Non-operating Temperature -40° to +65° C (-40° to +149° F) Operating Humidity 20% to 80% relative humidity, non-condensing Non-operating Humidity 5% to 95% relative humidity, non-condensing Operating Altitude -30 to 3,000 m (~10,000 ft) Non-operating Altitude -30 to 12,000 m (~40,000 ft) Minimum Clearance Front 1 m (39 in) Sides 2.5 cm (1.0 in) Top 2.5 cm (1.0 in) Back 15 cm (6.0 in) Weight and Dimensions LH 3 Height 494.
Notes: 12
1