hp netserver lh 6000 netraid-2m config guide - for Microsoft NT 4.0 Clusters PDF, 240K, 2/23/2002

lh6000nt2m
2/23/02 2
Server Configuration
Parameter Specification
I/O slots Added cards may be installed in any appropriate slot, considering the server
default boot order provided below.
Default boot order
IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI64-8, PCI64-7,
PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1
Local Storage
Controller Embedded SCSI, embedded DAC, NetRAID-1M, or
NetRAID-2M (in addition to shared storage NetRAID-2M controller)
Driver For embedded SCSI, sym_u3.sys, version 5.05.00, or later
For embedded DAC, NetRAID-1M or NetRAID-2M, mraidnt.sys, version 4.05
(all drivers obtained from Navigator CD-ROM, version L.20.00, or later)
Physical drive location Server internal drive bays, or HP external drive cabinet
(e.g., HP Rack Storage/12)
Disk drives Must be HP
SCSI bus Any HP cables that meet SCSI specifications, and any SCSI bus speed
SCSI IDs Any
System software
Navigator CD-ROM Version M.04.00, or later
Operating system
Service pack
Microsoft Window NT
Server 4.0, Enterprise Edition
SP5 or
SP6a and Microsoft
hotfix Q316743.
Please refer to the Microsoft
product support article at:
http://support.microsoft.com/default.aspx?scid=KB;EN-
US;q316743&ID=KB;EN-US;q316743
Power distribution
Layout Redundant power distribution units (PDUs) are recommended. See power cabling
diagram on page 6.
Shared Storage Configuration
Parameter Specification
Controller
Model HP NetRAID-2M Controller, Model P3411A, or P3475A
Number of controllers One or two
BIOS Disabled
Firmware Version H.01.08
(firmware obtained from Navigator CD-ROM, version M.04.00, or later)
Driver Mraidnt.sys, version 4.05
(driver obtained from Navigator CD-ROM, version L.20.00, or later)
NetRAID Assistant Version B.01.04, or later
(software obtained from Navigator CD-ROM, version L.20.00, or later)
SCSI ID 6, 7
Channels 0, 1
RAID levels 1, 5, 10, 50
Logical disks One per RAID array
Eight, maximum, per cluster