HP Netserver LH Pro NetRAID Config Guide for Windows NT4.0 Clusters

2
SPU
Model HP NetServer LH Pro 6/200 Model 1
Clock speed 200 MHz
No. of CPUs 2 (at least two are required)
BIOS version 4.05.14 PF or later
CPU cache Any size
RAM 128 MB minimum. Must be HP.
No. of power supplies 2
Hot swap cages May use for local storage; but not use for shared storage.
Local storage Internal or external, using any controller. Must use HP disks. See
Local
Storage below.
I/O slots: P9 - Shared storage controller (P8 if using NetRAID for local storage.)
P7 - Intra-cluster (Heartbeat) LAN
P6 - Client LAN
All others - Any other plug-in cards.
Storage
Local
Physical drive location SPU internal drive bays, or HP external drive cabinet (e.g., HP Storage
System/6), or any combination.
Disk drives Must be HP
Cables Must be HP and < 3 m total length for external drive cabinet.
Controller SPU embedded controller or any controller (any number, manufacturer or
driver) in any available I/O slot. Use P9 for NetRAID local storage. See
SPU I/O slots above.
Shared
Controller
Model HP NetRAID D4943A
Use with HP Storage System/6 and HP Cluster Adapter only.
No. of controllers 1 maximum
Firmware S.01.00
Driver 2.03
NetRAID Assistant A.01.09
SPU I/O slot P9 (P8 if using NetRAID for local storage.)
SCSI ID 6, 7
Channels 0 and 1 only
Do not use channel 2 for any purpose.
RAID level 1, 5, 10, and 50 only
Logical disks 1 per RAID array
6 maximum per NetRAID adapter
Configuration
options:
Cluster mode on (cache write-through, no hot spare)
Ultra SCSI disabled
Termination: wide channel or automatic
Set any other options as you prefer