HP Netserver LH Pro NetRAID Config Guide for Windows NT4.0 Clusters
3
Cabinet
Model HP Storage System/6 D3604B
No. of cabinets 1, 2
A cluster with a single storage cabinet has only one SCSI bus connected to
HP NetRAID channel 0. A cluster with 2 storage cabinets must have one
cabinet connected to NetRAID channel 0 and the other cabinet connected
to NetRAID channel 1.
SCSI IDs Any SCSI IDs except 6 or 7
SPU hot swap cages May not be used for shared storage.
Disk drives: HP 2.1 GB Hot-Swap Ultra SCSI Disk Module D3582B or D3582C
HP 4.2 GB Hot-Swap Ultra SCSI Disk Module D3583C
HP 4.2 GB 10K rpm Hot-Swap Ultra SCSI Disk Module D4903A
HP 9.1 GB Hot-Swap Ultra SCSI Disk Module D4289A
HP 9.1 GB 10K rpm Hot-Swap Ultra SCSI Disk Module D6019A
HP 18.2 GB Hot-Swap Ultra SCSI Disk Module D5039A
Cables HP Cluster Adapter D5957A
RAID arrays A RAID array (logical disk) must be composed of all the same disk model.
Different size or speed disks are not allowed in the same RAID array. Any
combination of disk models is allowed on a SCSI channel. Any
combination of disk models is allowed in a cluster.
LANs
Intra-cluster (Heartbeat) LAN Client LAN
LAN connection HP D5954A crossover cable or any
equivalent only
Any LAN
The intra-cluster LAN may only be
used for cluster node
communication via a crossover
cable. It may not be used for client
communication.
NIC:
Model HP D5013A (10/100TX PCI)
(or HP J3171A )
Any that is on both the HP
Tested Products List and the
Microsoft Hardware
Compatibility List.
Driver 2.24.00.0000 or later Any driver
SPU I\O slot P7 P6