hp netserver lp 2000r netraid-2m config guide - for Microsoft Windows 2000 A.S. Clusters. PDF, 81K, 10/2/2002

lp2000r2k2m
Server Configuration
Parameter Specification
Number of power
supplies
One standard, two required for redundancy
Note that in configurations with more than one NetRAID controller, fully
populated PCI or hard drive slots, the second power supply is required, and not
redundant.
I/O slots Added cards may be installed in any appropriate slot, considering the server
default boot order provided below.
Default boot order IDE CD-ROM, FDD, PCI slot 1, PCI slot 2, PCI slot 3, embedded SCSI
Local Storage
Controller Embedded SCSI, or NetRAID-1M
Driver For embedded SCSI, sym_u3.sys, version 5.07.00, or later
For NetRAID-1M, mraid2k.sys, version 5.20, or later
(all drivers obtained from Navigator CD-ROM, version L.20.00, or later)
Physical drive location Server internal drive bays, or HP external drive cabinet
(e.g., HP Rack Storage/12)
Disk drives Must be HP
SCSI bus Any HP cables that meet SCSI specifications, and any SCSI bus speed
SCSI IDs Any
System software
Navigator CD-ROM Version M.04.00, or later
Operating system
Service pack
Microsoft Windows
รข
2000 Advanced Server
Latest service pack version
Power distribution
Layout Redundant power distribution units (PDUs) are recommended. See power cabling
diagram on page 6.
Shared Storage Configuration
Parameter Specification
Controller
Model HP NetRAID-2M Controller, Model P3411A, or P3475A
Number of controllers One
BIOS Disabled
Firmware Version H.01.08
(firmware obtained from Navigator CD-ROM, version M.03.00, or later)
Driver Mraid2k.sys, version 5.20
(driver obtained from Navigator CD-ROM, version L.20.00, or later)
NetRAID Assistant Version B.01.04, or later
(software obtained from Navigator CD-ROM, version L.20.00, or later)
SCSI ID 6, 7
Channels 0, 1
RAID levels 1, 5, 10, 50
Logical disks One per RAID array
Eight, maximum, per cluster