hp netserver lp 2000r netraid-2m config guide - for Microsoft Windows 2000 A.S. Clusters. PDF, 81K, 10/2/2002

lp2000r2k2m
Shared Storage Configuration
Parameter Specification
Configuration options Cluster mode on
Cache write policy to Write thru
Enclosure
Disk drives Any HP drive supported by storage enclosure. Any combination of HP disk
models is allowed in an array, on a SCSI channel, or in a cluster.
Number of cabinets One or two
Model Rack Storage/12 D5989C, containing two D6025C SCSI controller cards
Status SCSI ID 5 (fixed)
Disk SCSI IDs 0โ€“3, 8โ€“15 (fixed)
Cables
SCSI Any two HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
See SCSI cabling diagram on page 5.
Power distribution
Layout Redundant power distribution units (PDUs) are recommended. See power cabling
diagram on page 6.
Microsoft
รข
and HP Certified Server Configuration
Parameter Specification
Server
I/O card slot PCI slot 1, NetRAID-2M shared storage controller
Network interfaces Embedded NICs for both intra-cluster (heartbeat) and client LANs
Boot device Embedded SCSI
Intra-Cluster (Heartbeat) LAN Configuration
Parameter Specification
Network
Connection HP D5954A crossover cable, or equivalent.
The intra-cluster LAN may only be used for cluster node communication. It may
not be used for client communication.
NIC
Quantity One
Model Embedded NIC โ€“ LAN A
Driver Hptxnt5.sys, version 4.02.27, or later
(driver obtained from Navigator CD-ROM L.20.00, or later)
10/21/02 3